Heat Exchanger for Systems with Pressurised Heat Carrier
Application
-
Delivery of large volumes of industrial gas to distribution
utilities to cover short supply - Inerting of installations
- Use of thermal energy stored in ocean water, rivers, lakes
or industrial waste water/cooling water to heat water in a
pressurised circuit
Design Features
- compact design; small footprint relative to capacity
- superior reliability
- constant gas outlet temperature independent of throughput
- no internal ice build-up
- available in various sizes for capacities from 100 to 10.000 Nm3/h
- made from stainless steel (copper registers available on request)
- optional: process instrumentation, process control
Technical Data
media | N2, O2, Ar, CO2, He, CH4, LNG |
heat-transfer media | surface water, waste water, process water or cooling loop water |
inlet temperature | heat carrier: +10°C to +80°C medium: -196°C to 0°C |
outlet temperature | heat-carrier: 2°C to 10°C below heat carrier inlet temperature medium: 0°C to +25°C |
max. operating pressure |
heat carrier: 4 bar, higher operating pressures are possible (please inquire) medium: 25 bar or 40 bar |
head loss | heat carrier: approx. 0.2 bar medium: approx. 0.5 bar |
throughput | heat carrier: 100 to 250 m3/h medium: 100 to 10000 Nm3/h |
connections | flange EN 1092-1 |
materials | 1.4541, 1.4571, SF-Cu |