TRANSINERT

Mobile Vaporiser / Interting System

Application

  • to render inert chemical warehouses, nuclear reactors, the holds of tankers, pipelines, coal mines, silos, etc. to eliminate or reduce the risk of fire and explosion
  • as a temporary source of gas during a plant outage or pipeline shutdown
  • to set up a gas delivery system at short notice and wherever it is needed independent of any gas supply infrastructure

Design Features

  • Compact, self-sustained system inside a container frame mounted on a container chassis
  • simple operation and low-maintenance
  • superior reliability
  • automatic power regulation

Technical Data

Medium/media nitrogen
Heat carrier water
Energy supply heating by integrated oil- or gas-fired 0.25 to 1.4 MW boiler
oil storage tank, if necessary
hot-water circuit with circulation pump
Evaporator inlet
temperature
heat carrier: +15°C to +70°C
medium: -196°C to -170°C
Evaporator outlet
temperature
heat carrier: 2°C to 5°C below inlet temperature
medium: 0°C to +25°C
Max. operating pressure heat carrier: 2 bar
medium: 25 bar
Throughput heat transfer medium: 100 / 200 m3/h
medium: 2000 to 10000 Nm3/h
Dimensions corresponding to 10-ft or 20-ft container
Weight 3 to 5 metric tons depending on dimensions and equipment
Connections Flange EN 1092-1
Materials 1.4541, 1.4571, SF-Cu